Hunter Valley Water Balance Report - 2012-13

Water balance component

Sources of water Distribution of water % of volume measured
 

Volume (ML)

% of total

Volume (ML)

% of total

 

Storage Volume

         
Volume in storage at start of year 1,028,260        
Volume in storage at end of year 1,017,711        
Change in storage 10,549 1%  0%  100% 
Barnard Reserve (4) - 0% - 0% 100%
Spills     52,273   100%
Storage net evaporation     49,989 5% 100%

Inflows

         
Storage inflows (1) 91,712 9%     100%
Downstream tributaries (2) 931,915 90%     50%
Subtotal 1,023,628 99%      

Net water diverted under riparian rights

         
Domestic and stock rights (3)     4,950 0%  0%
Native title rights     - 0%  
Subtotal     4,950 0%  

Net Water diverted under access licences

         
Domestic and stock     378  0%  
High security     7,182 1%  100%
General security     47,269 5%  100%
Local water utility     6,614 1%  100%
Major utility     28,401 3%  100%
Major Utility (dilution)     -  0% 100%
Supplementary water     34,423 3%  100%
Barnard Reserve (dilution)      - 0%  100%
Subtotal     122,267 12%  100%

Environmental water

         
Environmental flows (Plan)     30,984 3% 100% 
End of system flows (5)     825,987 80%  90%
Subtotal     856,971 83%  

Other outflows

         
Unaccounted difference (6)      - 0%  
Total
1,034,177
100%
1,034,177
100%
 

 

Notes:

  1. Calculated from Glenbawn and Glennies Creek Dams evaporation and releases, less storage drawdown and Barnard Reserve inflows.
  2. Downstream tributaries - assessed by mass balance at Greta - recorded trib flows were 631,635
  3. Basic rights are not metered. Values presented are those in the Water Sharing Plan.
  4. Barnard Reserve accumulates from an inter valley physical transfer. Total Barnard Reserve at end of month 0 Volume for 2012-13 only.
  5. Gauged at Greta (not the end) - flows greater than environmental target are provided.